Description
Specification
- LCD display, easy to read how inverter operates on LCD screen
- Compatible to generator
- 5-levels DIP switch, offering customized performance
- 9-levels battery selector, Enable to charge Lithium, Gel, lead-acid battery
- DC(Solar)/AC priority optional
- 4 levels charge current adjustable
- With RS232 communication port
- With BTS & GTS , optimising battery performance & start generator automatically
- Power saver Switch , Enable to minimize standby consumption
Applications
- Home Appliances
- Office Equipment
- Medical Equipment
- Sensitive Equipment
- General Use
- A&E 4KVA/24V Pure Sine Wave Inverter (TRANSFORMER BASE)
MODEL | A&E 4KVA PRO | A&E 5KVA PRO | A&E 7.5KVA PRO | |||||||
Default Battery System Voltage | 24VDC | 48VDC | 48VDC | |||||||
INVERTER OUTPUT | ||||||||||
Reted Power | 3KW | 4KW | 6KW | |||||||
Surge Rating (20ms) | 9.0KVA | 12KVA | 18KVA | |||||||
Capable Of Starting Electric Motor | 2HP | 3HP | ||||||||
Waveform | Pure sine wave/ same as input (bypass mode) | |||||||||
Nominal Output Voltage RMS | 220V/230V/240VAC(±10% RMS) | 220V/230V/240VAC(±10% RMS) | ||||||||
Output Frequency | 5OHz/60Hz±0.3 Hz | |||||||||
Inverter Efficiency(Peak) | >88% | |||||||||
Line Mode Efficiency | >95% | |||||||||
Power Factor | 1 | |||||||||
Typical Transfer Time | 10ms(max) 10ms(max) | |||||||||
AC INPUT | ||||||||||
Voltage | 230VAC | |||||||||
Selectable Voltage Range | 96~132VAC 155~280VAC(For Personal Computers) | |||||||||
Frequency Range | 50Hz/60Hz (Auto sensing) 40~80Hz | |||||||||
BATTERY | ||||||||||
Minimum Start Voltage | 10.0VDC /10.5VDC for12VDC mode (*2 for 24VDC, ) | |||||||||
Low Battery Alarm | 10.5VDC±0.3V for12VDC mode (*2 for 24VDC, ) | |||||||||
Low Battery Cutoff | 10.0VDC±0.3V for12VDC mode (*2 for 24VDC, ) | |||||||||
High Voltage Alarm | 16.0VDC±0.3V for12VDC mode (*2 for 24VDC, ) | |||||||||
High Battery Voltage Recover | 15.5VDC±0.3V for12VDC mode (*2 for 24VDC, ) | |||||||||
Idle Consumption-Search Mode | <25W when power saver on | |||||||||
CHARGER | ||||||||||
Output Voltage | Depends on battery tvpe | |||||||||
Charger AC Input Breaker Rrating | 30A | 40A | ||||||||
Overcharge Protection S.D. | 15.7VDC for 12VDC mode (*2 for 24VDC mode) | |||||||||
Maximum Charge Current | 75A | 65A | 50A | |||||||
BYPASS & PROTECTION | ||||||||||
Input Voltage Waveform | Sine wave (grid or generator) | |||||||||
Nominal Input Frequency | 50Hz or 60Hz | |||||||||
Overload Protection (SMPS Load) | Circuit breaker | |||||||||
Output Short Circuit Protection | Circuit breaker | |||||||||
Bypass Breaker Rating | 30A | 40A | ||||||||
Max Bypass Current | 30Amp | |||||||||
MECHANICAL SPECIFICATIONS | ||||||||||
Mounting | Wall mount | |||||||||
Dimensions (W*H*D) | 426*206*178 mm | 601*206*178 | ||||||||
Net Weight (Solar CHG) kg | 26 | 24.5 | 24.8 | 38.2 | 35.8 | 45.2 | 45 | 45.2 | 45 | |
Shipping Dimensions(W*H*D) | 570*335*300mm | 750*335*300mm | ||||||||
Shipping Weight (Solar CHG) kg | 29.1 | 27.5 | 27.5 | 42.3 | 40 | 49.5 | 49.3 | 49.5 | 49.3 | |
OTHER | ||||||||||
Operation Temperature Range | 0°C to 40°C | |||||||||
Storage Temperature | -15°C to 60°C | |||||||||
Audible Noise | 60dB MAX | |||||||||
Display | LCD | |||||||||
Standard Warranty | 1 year |